Background & Aims of the Study

Anaerobic baffled reactor (ABR) is one of the low-cost wastewater treatment systems; however, it has some limitations, such as insufficient standard nutrient outflow. Accordingly, it should be studied and developed. This research aims to determine the efficiency of a five-sectional reactor pilot and to upgrade it with an integrated aerated media filter in the reactor (integrated reactor) for municipal wastewater treatment.

Materials and Methods

This study was performed on a laboratory scale with field conditions in the Khoy City wastewater treatment plant. The ABR reactor operated for 270 days with a hydraulic retention time (HRT) of 48, 36, 24, and 18 hours, respectively. The Integrated anaerobic baffled reactor (IABR) was operated for 35 days with 24 hours of HRT, i.e., aeration time of 5 hours. The reactors were fed in line from the inflowing wastewater to the treatment plant. A 24-hour combined sampling was performed 224 times from the inflow and outflow of the system, and volatile suspended solids, total kjeldahl nitrogen (TKN), total phosphorus (TP), biochemical oxygen demand (BOD), chemical oxygen demand (COD), and Total Suspended Solids (TSS) parameters were measured and compared with the effluent disposal standard.

Results

The launch of ABR lasted 105 days, and its helpful operation lasted 200 days. In 18 to 48 hours, the reactor removed 79% to 91% of COD, 9% to 20% of TKN, 19% to 30% of phosphorus, and 89% to 94% of TSS. The IABR reached the effluent disposal standard in terms of TSS, BOD, COD, and phosphorus under 24 hours HRT, i.e., aeration time of 5 hours, and increased the COD removal efficiency by 6% compared to ABR under 24 hours HRT and the same conditions.

Conclusion

By integrating the final aerobic media filter in ABR while reducing the required HRT by 50%, its efficiency in achieving the effluent disposal standards increased compared to ABR. Therefore, this system can be used to treat municipal wastewater.

Language:
English
Published:
Archives of Hygiene Sciences, Volume:11 Issue: 2, Spring 2022
Pages:
127 to 136
magiran.com/p2462522  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!