Equivalent uniform dose and normal tissue complication probability of acute esophagitis in head-and-neck radiotherapy: Sensitivity to dose calculation accuracy
To quantify the influence of photon dose-calculation algorithm selection on the cervical esophagus (CE) dose indices and the derived equivalent uniform dose (EUD) and normal-tissue complication probability (NTCP) for acute esophagitis in patients with head-and-neck cancer (HNC).
The Fast Photon Effective Path (FPEP) and Collapsed-Cone Convolution Superposition (CCCS) algorithms on the Prowess Panther treatment planning system were compared for 30 patients (six tumor sites). The Lyman-Kutcher-Burmann (LKB) model was used to calculate the EUDs and NTCPs.
On average, the more simplistic FPEP algorithm overestimated the mean dose to CE planning organ-at-risk volumes (PRVs) by 2.0% (p = 0.003). The average absolute difference in mean dose was 2.7% and the maximum difference was 9.3%. The V5Gy, V10Gy, V15Gy, V20Gy, V25Gy and V30Gy values were significantly higher with FPEP, while the point-dose and D2cc hot spots were similar. In turn, the dose differences led to an underestimation of the LKB-model prediction of the EUD by 1.4% (p = 0.297). The mean absolute difference in EUD was 4.5% and the maximum difference was 15.3%. In the 14-50 Gy mean dose range, the resulting NTCPs with FPEP were lower on average by 2.6% than CCCS (p = 0.041).
In the group of HNC patients considered in this study, the EUD and NTCP for acute esophagitis showed to be moderately sensitive to the choice of dose-calculation algorithm. Despite an overestimated mean dose by the simpler algorithm, the NTCP underestimation, which can be large in some patients, is of clinical concern.
- حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران میشود.
- پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانههای چاپی و دیجیتال را به کاربر نمیدهد.