Abstract:
Background

Using sports supplements is common among athletes. The presence of anabolic steroids in sports supplements as a hormonal contaminant can increase production efficiency. Since anabolic steroids cause health problems and result in positive doping tests in athletes, it is important to investigate their presence in the supplement preparations consumed by athletes.

Objectives

This paper aims to simultaneously determine ten anabolic steroids by high-performance thin-layer chromatography (HPTLC) method in sports supplements.

Methods

Chromatographic analysis was conducted on glass silica gel 60F254 plates. The extracts loaded on silica gel plates are subjected to programed multiple development (PMD) to separate anabolic androgenic steroids (AASs). Densitometric scanning is carried out at the wavelength of 245 and 366nm. The method was validated according to the ICH guidelines.

Results

Spots at retardation factor (Rf) 0.72 (elution system 1), 0.4 (elution system 1), 0.29 (elution system 2), 0.25 (elution system 2), 0.1 (elution system 1), 0.65 (elution system 2), 0.59 (elution system 1), 0.44 (elution system 1), 0.8 (elution system 3), and 0.82 (elution system 3) values were recognized as 19-nor androstenedione, 19-nortestosterone, methyl testosterone, clostebol, stanozolol, trenbolone enanthate, oxymetholone, oxandrolone, testosterone enanthate, and nandrolone decanoate, respectively. The linear ranges were 25 - 250 μg/mL for oxymetholone, 7 - 50 μg/mL for 19-nor androstenedione, 19-nortestosterone, and oxandrolone, and 3 - 20 μg/mL for methyl testosterone, clostebol, stanozolol, trenbolone enanthate, testosterone enanthate, and nandrolone decanoate. The developed method is validated by acceptable precision (CV < 20%) and good accuracy (94% < R < 114%). The value of limit of detection (LOD) for all derivatives was in the range of 0.02 - 0.16 μg/spot (20-160 μg/g of supplement), while limit of quantitation (LOQ) was found to be in the range of 0.06 - 0.5 μg/spot (60 - 500 μg/g of supplement). Fifty sports supplement samples as real sample were collected and analyzed. None of the samples screened positive using the HPTLC method.

Conclusions

In the present study, the fast, cheap, and simple HPTLC method could be used for the multi-residue analysis of ten anabolic androgenic steroids in sports supplements.

Language:
English
Published:
Iranian Journal of Pharmaceutical Research, Volume:21 Issue: 1, Winter 2022
Page:
56
magiran.com/p2482046  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!