Active Length of Natural Gas Pipeline Subjected to Landslide

Author(s):
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

Natural gas transmission pipelines have a vital role in human life and thus, they are classified as lifelines. Long-term disruption in the pipeline operation due to landslides would have substantial direct and indirect consequences. Landslides are generally accompanied by large movements of the ground and result in the deformation of the pipeline and the surrounding soil. In buried pipelines, a significant length of the pipeline moves relative to the soil during a landslide. This movement activates the friction between the soil and the pipeline. The location where the relative movement and the friction diminish to zero is called the virtual anchor point. The clear distance between this point and the landslide where the relative movement occurs is known as the anchor length. Active length of the pipeline is the distance between two virtual anchor points on either side of the landslide and it is the sum of the two anchor lengths and the width of the landslide. During a landslide, the pipe within this length would be highly stressed and it is prone to failure. The active length is considered as the protected length and to reduce the risk of pipe rupture, construction of bents, joints, and equipment should be avoided within this length. Thus, an accurate estimate of this length is an important consideration in the design process. In this study, finite element analyses are carried out to evaluate the anchor lengths of common gas transmission pipelines in Iran. The analyses are performed using Ansys software platform. The pipe is modeled by nonlinear pipe elements and the pipe-soil interaction is modeled by Winkler springs. Buried pipes with diameters of 12, 20, 30, and 48 inches under internal pressure of zero, 500, 1000 psi in two different soils are analyzed. The results of the analyses indicate that the anchor length increases with increasing pipe diameter. The soil properties also significantly affect the anchor length, but the internal pressure has only marginal effect on the anchor length. The relevant equation of the anchor length provided by the PRCI guidelines is about 35% less than the anchor length obtained from the analyses. A more accurate equation for the anchor length is proposed in this study.

Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:38 Issue: 2, 2022
Pages:
3 to 15
magiran.com/p2497343  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!