Dose Assessment in Radiotherapy of Head and Neck Cancer after Metal Artifact Reduction in Neusoft-Philips Corporation CT Scanner: A Clinical Study

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Purpose

Metal artifacts cause to increase in the uncorrected dose evaluation during radiotherapy planning. This study aimed to evaluate the probable difference of the dose parameters calculated by the Treatment Planning System (TPS) in radiotherapy of head and neck cancer before and after metal artifact correction in Neusoft-Philips Corporation Computed Tomography (CT) images.

Materials and Methods

In the present study, the radiotherapy planning of the head and neck cancer from thirty patients was first performed on the CT default images with dental implants. The same processes were applied after performing a body standard metal kernel on the CT images to reduce the metal artifacts. The Gross Tumor Volume (GTV) and Organ At Risks (OARs) were contoured on the CT slices. The dosimetric parameters (mean, minimum, and maximum) for the GTV and OARs (eyes and spinal cord) were obtained for both sets of CT images (defaults and filtered). Wilcoxon signed-rank test was used to calculate the probability dose variations between the two sets.

Results

There are significant differences in several dose parameters between the default and filtered CT images (P-value < 0.05). These dosimetric parameters are related to the GTV (mean dose), spinal cord (minimum and mean doses), right eye (maximum dose), as well as left eye (mean dose). The average range of dose differences between the default and filtered images was obtained; 1.12%-3.11% for the GTV as well as 0.22%-12.05% for the OARs.

Conclusion

Based on the results, the body standard metal kernel can cause a significant difference in several dosimetric parameters of GTV and OARs during the radiotherapy of head and neck cancer. Therefore, it is recommended to make a metal artifact correction on CT images for accurate dose calculation before designing a treatment plan.

Language:
English
Published:
Frontiers in Biomedical Technologies, Volume:10 Issue: 1, Winter 2023
Pages:
32 to 37
magiran.com/p2525391  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!