Critical Organ Dose Estimation from Tc-99m-MIBI in Nuclear Medicine Cardiology Based on Distribution Data in Rats

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Purpose

Calculating the organs' radiation dosage in cardiac nuclear medicine procedures is essential in order to identify critical organs, radiation risk assessment and optimization dose value in the injection of radiopharmaceutical drugs. In this study, the biological distribution of 99mTc-2-Methoxyisobutylisonitrile) 99mTc-MIBI as the most common radiopharmaceutical in a cardiac study in human organs based on animal samples was investigated.

Materials and Methods

After 99mTc-MIBI preparation, radiopharmaceutical was injected into 15 rats. After sacrificing rats, the uptake of radiopharmaceuticals in critical organs at 15, 30, and 45 minutes was measured using an High Purity Germanium (HPGE) detector and the percentage of injected dose per gram of organs was calculated. The cumulative activity was calculated from the radiopharmaceutical transformation diagram with time. The absorption of a radioactive complex in human organs based on animal data was calculated by applying a correction factor. The organs dose was calculated using S factor and the effective dose was calculated using tissue weighting factors.

Results

The mean effective dose per unit of activity was 0.0062 mSv/MBq. The mean effective dose of 27.5 mCi radiopharmaceutical injection was 6.3 mSv. In this study, the absorbed dose in blood, heart, lung, thyroid, liver, spleen, stomach wall, muscle, and bone was calculated as 0.28, 2.92, 1.85, 24.82, 11.13, 7.03, 20.95, 1.11, 4.97, and 22.22 mGy, respectively.

Conclusion

The effective dose of human organs based on the animal model in the study of cardiac nuclear medicine was evaluated by injection of 99mTc-MIBI radiopharmaceutical. The kidneys, salivary glands, thyroid, and spleen were the most critical organs that should be considered in dose optimization studies. The effective dose limit was 28% lower than the values reported in international references.

Language:
English
Published:
Frontiers in Biomedical Technologies, Volume:10 Issue: 1, Winter 2023
Pages:
102 to 108
magiran.com/p2525399  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!