Role of Lesion-to-Background Activity Ratio and Background Activity in Optimization of Reconstruction Protocols for FDG PET/CT Images of Overweight Patients: A Phantom Study

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
 Background

 The quality of positron emission tomography/computed tomography (PET/CT) images plays an important role in tumor detection. This imaging method often yields poor-quality images of overweight patients due to the high level of noise, originating from scattering and photon attenuation.

Objectives

 The point spread function (PSF) is mostly used to enhance the spatial resolution and signal-to-noise ratio (SNR); however, it is known to increase the edge artifacts. The time-of-flight (TOF) principle can reduce edge artifacts in PSF modeling and improve lesion detection, especially in the thorax. The present study aimed to assess these two new techniques by applying different reconstruction parameters.

Materials and Methods

 An in-house phantom with an inner diameter of 35 cm was used for the simulation of overweight patients. Lesion-to-background ratios (LBRs) of 2: 1 and 8: 1, as well as background activity concentrations of 3 and 5 kBq/cc, were considered in this study. The list-mode data were reconstructed with various reconstruction protocols, numbers of subsets, and filter sizes. Quantitative analyses, including the coefficient of variation (COV), SNR, and recovery coefficient (RC), were also carried out. Moreover, box-and-whisker plots were performed.

Results

 At LBR of 2: 1, by changing the protocol from ordered subset expectation maximization (OSEM) to OSEM + PSF + TOF, the median value of SNR for 13-mm lesions (37 mm) increased by 39.25% and 53.45% (42.22% and 56.21%), at background activity concentrations of 3 and 5 kBq/cc respectively. However, at LBR of 8: 1, the corresponding values were 33.22% and 48.94% (40.22% and 52.15%) at background activity concentrations of 3 and 5 kBq/cc respectively.

Conclusion

 The TOF protocols were strongly recommended for both background activity concentrations at LBR of 2: 1 and for the low background activity concentration at LBR of 8: 1, especially when using smaller filter sizes. Moreover, subset numbers of 18 and 24 were appropriate for all protocols. However, a smaller subset number was suitable when a low background activity concentration and a smaller filter size were applied, especially at a lower LBR.

Language:
English
Published:
Iranian Journal of Radiology, Volume:20 Issue: 1, Jan 2023
Page:
4
magiran.com/p2557431  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!