Evaluation of Two Pain Assessment Methods (Tactile and air Blast) for Comparison the Effectiveness of Nd:YAG Laser Therapy and Non-Laser Therapy on Dentin Hyper Sensitivity Treatment: a systematic Review and Meta-analysis

Message:
Article Type:
Review Article (دارای رتبه معتبر)
Abstract:

Statement of the Problem: 

Dentin hypersensitivity (DH) is a common irritating condition. A precise sensitive test for its assessment can greatly aid in appropriate treatment planning.

Purpose

This meta-analysis aims to compare the air blast and tactile tests for assessment of the efficacy Nd:YAG laser therapy versus non-laser treatments for DH in short-term and long-term follow-ups.

Materials and Method

for this review, an electronic search of the literature was carried out in three databases by two researchers for English articles published until March 10, 2021. Pooling of the data extracted from the selected articles was performed according to the PRISMA statement by the random-effect model. The mean difference (MD) and 95% confidence interval (CI) of pain score before the treatment onset and during the follow-up period according to the visual analog scale (VAS) were calculated. The level of heterogeneity was assessed by the I2 test, and a funnel plot was drawn to assess the publication bias of the reviewed studies.

Results

Of 152 articles primarily retrieved, 9 randomized clinical trials (RCTs) using the air blast test and 4 RCTs using the tactile test were subjected to quantitative synthesis. In the short-term follow-up and immediately after treatment, the air blast test showed superiority of laser therapy compared with non-laser treatments (SMD: 0.55, 95% CI: 0.05-1.04, p= 0.03). However, this difference was not significant according to the tactile test (SMD: 0.48. 95% CI: 0.01-0.96, p= 0.06). In the long-term follow-up, the difference between laser therapy and non-laser modalities was not significant according to both air blast (SMD= -0.38, 95% CI: -1.43-0.67, p= 0.48) and tactile (SMD=0.0, 95% CI: -0.38-0.38, p= 0.99) tests.

Conclusion

Comparison of laser therapy and non-laser modalities in the short-term revealed higher sensitivity of the air blast test due to its mechanism of action compared with the tactile test. Further studies are required to interpret the results in the long-term follow-up.

Language:
English
Published:
Journal of Dentistry, Shiraz University of Medical Sciences, Volume:24 Issue: 2, Jun 2023
Pages:
168 to 181
magiran.com/p2577368  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!