Performance of Iterative Reconstruction in Image Space Algorithm in Combination with Automatic Tube Current Modulation Compared to Filtered Back Projection in Brain CT Scan
Author(s):
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background
High-quality images with minimum radiation dose are considered a challenge in Computed Tomography (CT) scans.Objective
The current study aimed to assess the efficacy of the Iterative Reconstruction in Image Space (IRIS) algorithm combined with Automatic Tube Current Modulation (ATCM) compared to Filtered Back Projection (FBP) in brain CT scans.Material and Methods
In this cross-sectional study, 200 patients underwent to brain CT scan, and images were then reconstructed using both FBP and IRIS. The CT Number (CTN), noise, and Signal-to-Noise Ratio (SNR) were computed for different tissues from CT images. The performance of two algorithms under different exposure conditions was evaluated using a water phantom. Two experienced radiologists assessed the image quality. Volume CT Dose Index (CTDIvol) and Dose Length Product (DLP) were recorded for each scan.Results
FBP reconstruction exhibited higher noise and lower SNR compared to IRIS, both with and without ATCM. Noise levels significantly increased for FBP combined with ATCM. Subjective analysis showed higher performance for IRIS without ATCM compared to other approaches. The mean CTDIvol with and without ATCM was 20.04±3.33 and 36.37±4.65 mGy, respectively. In the phantom study, the noise with IRIS remained lower than that with FBP even with a 42% dose reduction. Conclusion
IRIS algorithm can preserve the image quality when radiation dose is significantly reduced by ATCM in brain CT scan. Implementation of IRIS combined with ATCM is recommended for brain CT examinations.Keywords:
Language:
English
Published:
Journal of Biomedical Physics & Engineering, Volume:14 Issue: 4, Jul-Aug 2024
Pages:
379 to 388
https://www.magiran.com/p2747635
سامانه نویسندگان
از نویسنده(گان) این مقاله دعوت میکنیم در سایت ثبتنام کرده و این مقاله را به فهرست مقالات رزومه خود پیوست کنند.
راهنما
مقالات دیگری از این نویسنده (گان)
-
Effect of Iterative Reconstruction Algorithm in Image Space on Image Quality In Abdominal-Pelvic CT wWith Contrast
*, Sohrab Kolivand
Journal Of Isfahan Medical School, -
Correlation between Hemoglobin and Hematocrit Levels with CT Number of Superior Sagittal Sinus
Payam Hashemi, *, Safoora Nikzad, Kamaledin Hadei
Paramedical Sciences and Military Health,