فهرست مطالب

Frontiers in Dentistry - Volume:12 Issue: 12, Dec 2015

Frontiers in Dentistry
Volume:12 Issue: 12, Dec 2015

  • تاریخ انتشار: 1395/04/06
  • تعداد عناوین: 10
|
  • Leila Khojastepour, Shirin Kolahi, Nazi Panahi, Abdolaziz Haghnegahdar Pages 868-873
    Objectives
    Differential diagnosis of bifid mandibular condyle (BMC) is important, since it may play a role in temporomandibular joint (TMJ) dysfunctions and joint symptoms. In addition, radiographic appearance of BMC may mimic tumors and/or fractures. The aim of this study was to evaluate the prevalence and orientation of BMC based on cone beam computed tomography (CBCT) scans.
    Materials And Methods
    This cross-sectional study was performed on CBCT scans of paranasal sinuses of 425 patients. In a designated NNT station, all CBCT scans were evaluated in the axial, coronal and sagittal planes to find the frequency of BMC. The condylar head horizontal angulations were also determined in the transverse plane. T-test was used to compare the frequency of BMC between the left and right sides and between males and females.
    Results
    Totally, 309 patients with acceptable visibility of condyles on CBCT scans were entered in the study consisting of 170 (55%) females and 139 (45%) males with a mean age of 39.43±9.7 years. The BMC was detected in 14 cases (4.53%). Differences between males and females, sides and horizontal angulations of condyle of normal and BMC cases were not significant.
    Conclusion
    The prevalence of BMC in the studied population was 4.53%. No significant difference was observed between males and females, sides or horizontal angulations of the involved and uninvolved condyles.
    Keywords: Mandibular Condyle, Prevalence, Cone, Beam Computed Tomography
  • Hamid Jalali, Leyla Sadighpour, Ali Miri, Ahmad Reza Shamshiri Pages 874-881
    Objectives
    The purpose of this in vitro study was to compare the marginal adaptation and fracture resistance of a zirconia-based all-ceramic restoration with two preparation designs.
    Materials And Methods
    Twenty-four mandibular premolars were randomly divided into two groups (n=12); the conventional group received a peripheral shoulder preparation and the modified group received a buccal shoulder and proximal/lingual chamfer preparation. The marginal fit of the zirconia crowns (Cercon) was evaluated using a stereomicroscope. After cementation, load was applied to the crowns. The mean fracture load and the mean marginal gap for each group were analyzed using t-test (P=0.05).
    Results
    The mean marginal gap was 71±16µm in the conventional group and 80±10µm in the modified group, with no significant difference (P=0.161). The mean fracture strength was 830±153N for the conventional group and 775±125N for the modified group, with no significant difference (P=0.396). All but one fracture occurred in the veneering ceramic.
    Conclusion
    Less aggressive preparation of proximal and lingual finish lines for the preservation of tooth structure in all-ceramic restorations does not adversely affect the marginal adaptation or fracture strength of the final restoration.
    Keywords: Zirconium Oxide, Computer, Aided Design, Prosthesis Failure, Dental Marginal Adaptation
  • Amirhossein Mirhashemi, Mohammad Sadegh Ahmad Akhoundi, Sedigheh Sheikhzadeh, Nafiseh Momeni, Ahmadreza Dehpour, Mojgan Alaeddini, Yasaman Kheirandish, Homa Farhadifard, Elahe Ansari Pages 882-889
    Objectives
    Fluoxetine is a selective serotonin re-uptake inhibitor (SSRI) widely used for depression, bipolar disorder, anxiety and obsessive-compulsive disorder. The aim of this study was to assess the effect of fluoxetine on orthodontic tooth movement (OTM) in rats.
    Materials And Methods
    Forty-five male Wistar rats were randomly divided into three groups namely the control group (no medication), saline and fluoxetine dissolved in saline. In all groups, nickel titanium closed-coil spring was used between the left maxillary central incisor and first molar to exert 60g force at 2mm activation. Radiographs were taken at one and 21 days. After 21 days, the rats were sacrificed. The distance between the first and second molar teeth, optical density of bone, periodontal ligament (PDL) width, lacuna length and depth and number of osteoclasts were measured and compared among the groups.
    Results
    Tooth movement significantly increased in the fluoxetine group (P=0.005). No significant differences were found in osteoclast count (P=0.069). The PDL width in the mesioapical region of root was significantly different among the groups (P=0.015). Statistical analysis did not show significant differences in depth or length of lacunae in any examined part of the root (P>0.05). Bone densitometry results showed that in fluoxetine group, density of bone in all four areas (alveolar bone, hard palate, skull and mandibular bone) significantly decreased from day one to day 21 (P
    Conclusion
    This study indicated that fluoxetine decreased bone density, which resulted in subsequently greater tooth movement in rats; however, further studies are needed on humans.
    Keywords: Fluoxetine, Tooth Movement, Rats
  • Narmin Mohammadi, Mahmoud Bahari, Soodabeh Kimyai, Behnam Rahbani Nobar Pages 890-898
    Objectives
    Composite repair is a minimally invasive and conservative approach. This study aimed to evaluate the effect of an additional hydrophobic resin layer on the repair shear bond strength of a silorane-based composite repaired with silorane or methacrylate-based composite.
    Materials And Methods
    Sixty bar-shaped composite blocks were fabricated and stored in saline for 72 hours. The surface of the samples were roughened by diamond burs and etched with phosphoric acid; then, they were randomly divided into three groups according to the repairing process: Group 1: Silorane composite-silorane bonding agent-silorane composite; group 2: Silorane composite-silorane bonding agent- hydrophobic resin-silorane composite, and group 3: Silorane composite-silorane bonding agent-hydrophobic resin methacrylate-based composite. Repairing composite blocks measured 2.5×2.5×5mm. After repairing, the samples were stored in saline for 24 hours and thermocycled for 1500 cycles. The repair bond strength was measured at a strain rate of 1mm/min. Twenty additional cylindrical composite blocks (diameter: 2.5mm, height: 6mm) were also fabricated for measuring the cohesive strength of silorane-based composite. The data were analyzed using One-way ANOVA and the post hoc Tukey’s test (α=0.05).
    Results
    Cohesive bond strength of silorane composite was significantly higher than the repair bond strengths in other groups (P
    Conclusion
    Application of an additional hydrophobic resin layer for repair of silorane-based composite with a methacrylate-based composite enhanced the repair shear bond strength.
    Keywords: Silorane Composite Resin, Hydrophobic, Hydrophilic Interactions, Dental Restoration Repair, Shear Strength
  • Jaber Yaghini, Narges Naghsh Naghsh, Elaheh Attaei Attaei, Reza Birang Birang, Ehsan Birang Pages 899-905
    Objectives
    Scaling and root planing (SRP) is one of the most commonly used procedures during periodontal treatment. The aim of this study was to evaluate the root surface roughness after SRP with erbium: yttrium aluminum garnet (Er:YAG) laser compared to ultrasonic and hand instruments.
    Materials And Methods
    In this experimental study, 56 extracted sound single-rooted teeth with moderate level of calculus were selected and randomly divided into four groups: SRP was performed with Er:YAG laser (100 mJ pulse, 1W, 10Hz, VSP and contact mode, with 50% water and air) in group one, hand instrument in group two and ultrasonic tool in group three. Group four was considered as the control group. After SRP, all samples were cut by Servocut cutting machine into pieces with 3×3×2mm dimensions. The samples were mounted in acrylic resin. The surface roughness of the samples was evaluated with profilometry, and the data were analyzed using one-way ANOVA and Tukey’s test in SPSS software.
    Results
    Surface roughness was higher in laser and lower in ultrasonic group compared to other groups. There was a significant difference in surface roughness between laser and ultrasonic groups (P=0.043), but there was no significant difference in surface roughness among other groups (P>0.05).
    Conclusion
    The results of this study showed that surface roughness after SRP with Er:YAG laser was not higher than that after manual SRP, but the former value was higher than that after SRP with ultrasonic instrument.
    Keywords: Dental Cementum, Lasers, Solid, State, Root Planing
  • Amir Alireza Rasouli Ghahroudi, Ali Homayouni, Amir Reza Rokn Rokn, Fatemeh Kia, Mohammad Javad Kharazifard Kharazifard, Afshin Khorsand Pages 906-912
    Objectives
    Anterior maxilla, known as the esthetic zone, plays an important role in facial and smile esthetics. This study assessed the frequency of implant treatments in the esthetic zone of patients presenting to Dental Implant Department of Tehran University during 2002-2012.
    Materials And Methods
    This descriptive study was conducted on dental records of patients receiving implant treatment during 2002-2012. Patient records were retrieved from the archives and patient demographics, implant characteristics, failure rate, prevalence of complications and implant systems were collected. The data were reported as frequency and percentage.
    Results
    Of a total of 2,381 implants placed in the mentioned time period, 492 (20.8%) had been placed in the anterior maxilla and 531 (22.3%) had been placed in the anterior mandible from canine to canine. Timing of implant placement was immediate in 12.0%, early in 0.5% and late in 87.4%. Survival rate was 99.1%. Rate of failure was 0.8%. Failure rate was 0.4% in the maxillary and 1.1% in the mandibular canine to canine region. Complications were reported in 10.1% of patients. Rate of complications was 18.3% in the maxillary canine to canine, 8.9% in the mandibular canine to canine, 18.1% in the maxillary first premolar to first premolar and 9.5% in the mandibular first premolar to first premolar. The frequency of bone grafts placed in these areas was 17.6%, 33.9%, 13.6%, 32.1% and 14.3%, respectively.
    Conclusion
    Of implants placed in our center, around 20% were in the anterior maxilla, and delayed implant placement was the most commonly adopted technique.
    Keywords: Frequency, Esthetic Zone, Dental Implant
  • Masoud Fallahinejad Ghajari, Ladan Eslamian, Azam Naji Rad, Seyyedeh Pouya Pages 913-920
    Objectives
    This study aimed to compare the incidence of white spot lesions (WSLs) around orthodontic bands following the application of two glass ionomer (GI) cements namely GC Gold Label and GC Fuji Plus for six to 12 months.
    Materials And Methods
    A total of 186 permanent first molars of orthodontic patients requiring banding of at least two permanent first molars were chosen. The teeth were examined for caries and presence of WSLs by visual inspection and by DIAGNOdent (scores 0-29). Orthodontic bands were randomly cemented to the right or left molars using GC Gold Label or GC Fuji Plus GI cements. Samples were randomly divided into three groups and bands were removed after six, nine and 12 months in groups 1, 2 and 3, respectively. The teeth were then examined for caries and presence of WSLs by visual inspection. DIAGNOdent was used on the buccal and lingual surfaces to determine the presence of WSLs. The data were statistically analyzed using one-way ANOVA, multivariate repeated measures ANOVA, the Kruskal Wallis and the Mann-Whitney tests.
    Results
    Totally 174 teeth were evaluated. DIAGNOdent scores were not significantly different before cementation and after removal of bands in buccal and lingual surfaces of the teeth in the two cement groups. Lesions simulating WSLs were seen in 21 out of 174 teeth but DIAGNOdent scores were not indicative of caries.
    Conclusion
    Remarkable WSLs were not detected visually or by DIAGNOdent at six, nine or 12 months following the cementation of bands with two GI cements.
    Keywords: Dental Caries, Glass Ionomer Cements, Dental Enamel, Decalcification, Pathologic
  • Ahmad Najafi Abrandabadi, Seyedeh Mahsa Sheikh Al Eslamian, Narges Panahandeh Pages 921-925
    Objectives
    The aim of this in-vitro study was to assess the thermal effect of light emitting diode (LED) light curing unit on the enamel etching time.
    Materials And Methods
    Three treatment groups with 15 enamel specimens each were used in this study: G1: Fifteen seconds of etching, G2: Five seconds of etching, G3: Five seconds of etching plus LED light irradiation (simultaneously). The micro shear bond strength (µSBS) of composite resin to enamel was measured.
    Results
    The mean µSBS values ± standard deviation were 51.28±2.35, 40.47±2.75 and 50.00±2.59 MPa in groups 1, 2 and 3, respectively. There was a significant difference between groups 1 and 2 (P=0.013) and between groups 2 and 3 (P=0.032) in this respect, while there was no difference between groups 1 and 3 (P=0.932).
    Conclusion
    Simultaneous application of phosphoric acid gel over enamel surface and light irradiation using a LED light curing unit decreased enamel etching time to five seconds without compromising the µSBS.
    Keywords: Acid Etching, Dental, Dental Enamel, Curing Lights, Dental
  • Hossein Afshar Afshar, Mehdi Ghandehari, Banafsheh Soleimani Pages 926-931
    Objectives
    It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs) for the primary maxillary and mandibular first and second molars following re-crimping.
    Materials And Methods
    This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA.
    Results
    The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P
    Conclusion
    Considering the significant reduction in the marginal circumference of pre-crimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping.
    Keywords: Stainless Steel, Crowns, Dental Marginal Adaptation, Molar
  • Shima Aalaei, Abolhassan Abolhassani, Fatemeh Nematollahi, Elaheh Beyabanaki, Amir Ali Mangoli Pages 932-935
    Implant-supported craniofacial prostheses are made to restore defective areas in the face and cranium. This clinical report describes a technique for fabrication of an orbital prosthesis with three adjacent implants in the left lateral orbital rim of a 60-year-old woman. Selection of appropriate attachment system (individual magnetic abutments versus bar-clip attachment) for implant-supported orbital prostheses depends upon the position of implants. Bar-magnetic attachment has been selected as the retention mechanism in the present case.
    Keywords: Dental Implant, Ocular Prosthesis, Magnetics, Innovative Therapy, Prosthesis Retention