Evaluation of Platform Switched Laser-Lok implant on the stress distribution of crestal boneby Finite Element Analysis

Message:
Abstract:
Background
This research analyzes the effect of platform switching design of Laser-Lok implants on the stress distribution in crestal bone of the Laser-Lok implant collar and its surrounding bone interface through Finite Element Analysis (FEA). The results are compared with control implant to show the effect of Laser-Lok implants platform switching design on the stress distribution in crestal bone.
Material And Methods
Three-dimensional modeles of the Laser-Lok implant with platform switching, the control implant (a Laser-Lok implant with same size abutment), and the mandible bone is generated for the FEA. Each implant is assembled on the mandible bone in pre-molar considering the proper boundary condition. It should be mentioned that the control implant is similar in all features to the independent implant (LL) except from the size of abutment. After meshing and considering the proper elements regarding the mastication forces and normal condition, a 100N of axial and oblique loading with angles of 15 and 45 angle is applied to the centre of the abutments of both Independent Laser-Lok implant and control implant on same condition.
Results
Under different loading conditions the independent implant has shown better results and lower stress distribution on surrounding crestal bone, comparing with control implant. Results demonstrate that the platform switching design will not only ignore the Laser-Lok fixture advantage of reducing the shear forces and bone loss but also will reduce stress concentration on the critical points of upper parts of the crestal bone. Hence transferring the stress distribution to the lower parts of the crestal bone-collar interface.
Conclusion
It should be considered that only reducing the shear forces is not enough to decrease crestal bone loss. In this regard, excluding the biological factors should also be considered. Therefore, the platform switching design is proposed as a way to inhibit the interstitial fluid flow to surrounding tissues by creating a platform on the abutment-fixture interface and it is a biological advantages. Total results indicate that Laser-Lok implant with platform switching has not only all the advantages of control implant in reducing the shear forces on crestal bone-collar interface but also has its own advantage of reducing the crestal bone loss by eliminating the biological factor.
Language:
Persian
Published:
Lasers in Medicine, Volume:8 Issue: 2, 2012
Page:
35
magiran.com/p1021809  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!