The Comparison of Vertical Margin Discrepancy in Casting Fabricated With Metal Ring, Ringless and Metal Ring With Hygroscopic Expansion Investment Systems

Message:
Abstract:
Background
The use of casting ring to produce accurate casting has been challenged with the introduction of a ringless casting technique. This study compared the vertical margin discrepancy of castings fabricated with the ringless technique, conventional (ring and liner) technique and conventional technique with hygroscopic expansion investment systems.
Objectives
The current study aimed to determine and compare the mean values of vertical margin discrepancies of castings in three investing procedures: the ringless technique and conventional investing technique.
Materials And Methods
In the first step, 39 coping wax patterns for Porcelain fused to metal restoration (P.F.M). With chamfer finish line were fabricated on the metal die and then divided into three groups of 13. The first group used conventional investing (with ring and liner), the second group used the ringless technique and the third group used the conventional ring technique with liner and hygroscopic expansion. All groups were invested using Thermovest phosphate bonded investment. Then wax patterns were cast with Ni-Cr alloy (super cast). Castings were divested, cleaned and seated on the metal die after minimal internal surface adjustment. The vertical margin discrepancy was measured in four sites: on the buccal, lingual, mesial and distal surfaces of the die. Castings were measured on an optical microscope. The vertical margin discrepancy in each group was used for statistical analysis.
Results
After statistical evaluation, the following results were obtained: the mean vertical margin discrepancy for conventional investing was 156.72 ± 64.67µ; for the ringless technique it was 117.3 ± 26.77µ; and for the conventional metal ring technique with hygroscopic expansion it was 96.15 ± 38.31 µ. There is a significant difference between castings of the conventional investing technique and the ringless and ring plus hygroscopic expansion techniques (P < 0.001). No significant difference was found between the ringless and ring plus hygroscopic expansion techniques (P = 0.183).
Conclusions
The castings fabricated from the ringless technique with non-precious alloy are acceptable. This investing system is useable for the fabrication of fixed restorations.
Language:
English
Published:
Avicenna Journal of Dental Research, Volume:7 Issue: 2, Dec 2015
Page:
5
magiran.com/p1474443  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!