Accuracy of Inferior Vena Cava, Aorta, and Jugular Vein Ultrasonographic Diameters in Identifying Pediatric Dehydration

Abstract:
Introduction
Evaluating intravascular volume is an important but complicated matter in management of critically ill patients, especially in children. Although invasive techniques have the ability to accurately estimate the intravascular volume, but they have dangerous side effects. Therefore, the present study was designed with the aim of comparing the diagnostic accuracy of sonographic diameters of inferior vena cava (IVC), aorta, internal jugular vein (IJV), and IVC/aorta ratio in identifying pediatric dehydration in children presented to the emergency department (ED).
Methods
The present prospective cross-sectional study was carried out with the aim of determining the diagnostic accuracy of sonographic diameters of IVC, IJV, and aorta, in estimation of dehydration rate for children presented to the ED with mild to moderate dehydration. Their screening performance characteristics, such as area under the ROC curve, sensitivity and specificity, were calculated and used for this purpose. The data were analyzed using STATA 11.0 and 0.05 was considered as significance level.
Results
In the end, 54 patients were enrolled in the study (57.4% male, mean age of 4.9 ± 2.7 years). Area under the ROC curve for IVC in diagnosis of moderate dehydration in sagittal and transverse planes were 0.775 (95% CI: 0.65 – 0.91) and 0.8086 (95%CI: 0.96 – 0.93), respectively. In addition, the diameter of aorta in this regard were 0.658 (95%CI: 0.51 – 0.81) for the sagittal and 0.7126 (95% CI: 0.57 – 0.86) for the transverse plane. IJV diameter had an area under the curve of 0.7332 (95% CI: 0.59 – 0.88). Comparing the area under the ROC curves for the studied parameters showed that IVC diameter in the sagittal (p = 0.004) and transverse (p
Conclusion
Based on the findings of the present study, it seems that IJV, IVC, and aorta diameters are not very accurate for determining the condition of pediatric dehydration, since even sonographic IVC diameter, which was more accurate than the other parameters, had a sensitivity of 81.48% and specificity of 48.15% in differentiating mild and moderate dehydration.
Language:
Persian
Published:
Iranian Journal of Emergency medicine, Volume:2 Issue: 4, 2015
Pages:
174 to 181
magiran.com/p1563597  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!