Contrast and spatial frequency modulation for diagnosis of amblyopia: An electrophysiological approach

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Purpose
To evaluate the diagnostic value of visual evoked potentials (VEPs) and to find out which test setting has the most sensitivity and specificity for amblyopia diagnosis.
Methods
Thirty-three adult anisometropic amblyopes were intended in this study and were tested for visual evoked potentials with different stimulus conditions including three spatial frequencies [1, 2, and 4-cycles-per-degree (cpd)] at four contrast levels (100, 50, 25, and 5%).We also tested psychophysical contrast sensitivity and compared the results with electrophysiological ones. We plotted Receiver Operating Characteristic (ROC) curve for each VEP recording and psychophysical contrast sensitivity to evaluate the area under the curve, sensitivity, specificity, and cutpoint value of each test stimulus for detecting amblyopic eyes.
Results
Thirty-three amblyopic and 33 non-amblyopic eyes were examined for psychophysical contrast sensitivity and VEPs. Area under the ROC curve (AURC) findings showed that VEP with different stimulus settings can significantly detect amblyopic eyes, as well as psychophysical contrast sensitivity test. We found that P100 amplitudes had the largest AURC in response to stimuli of 2-cpd spatial frequency at 50 (P < 0.001) and 25% (P < 0.001) contrast levels, respectively. Cut-off amplitudes for these stimuli were 8.65 and 4.50 mV, which had a sensitivity of 0.758 and 0.697 and a specificity of 0.788 and 0.848, respectively. The sensitivity and specificity of VEP P100 amplitude in response to the stimuli with 2 cpd spatial frequency and 50 and 25% contrast were greater than the findings obtained from psychophysical contrast sensitivity test.
Conclusion
According to our findings, assessment of VEP amplitudes in response to stimuli of 2-cpd spatial frequency at 50 and 25% contrast levels can best detect amblyopia with highest sensitivity and specificity and thus, are the protocols of choice for detection of amblyopic eyes.
Language:
English
Published:
Journal of Current Ophthalmology, Volume:31 Issue: 1, Mar 2019
Pages:
72 to 79
magiran.com/p1944977  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!