Evaluation of direct evaporative cooling system (fan-pad) in greenhouse under different environmental conditions

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

The cultivation of greenhouse crops is an advance in agricultural production technology that is increasing from temperate to warmer regions. However, greenhouse protects crops in a bad weather condition, but high temperature and humidity in the tropics have a converse effect on a production of crops. Therefore, in these regions, it is necessary to reduce the temperature inside the greenhouse. Since the design of the cooling system is highly dependent on environmental conditions, it is difficult to develop an appropriate system that provides local climate conditions for product growth. Therefore, in this research, the performance of fan-pad cooling system was studied in different climatic conditions. For this purpose, the greenhouse environment was first modeled using TRNSYS software. After verifying the model with experimental results, the system's ability to cool the greenhouse and system performance was evaluated relative to the parameters of air velocity, temperature and humidity ratio. The results showed that in ambient conditions with dry bubble temperature and humidity ratio less than 40˚C and 0.015 kg/kg, direct evaporative cooling system (fan-pad) at an air velocity of 1.25 m/s was a suitable method for cooling the greenhouse and provides suitable conditions for product growth. The cultivation of greenhouse crops is an advance in agricultural production technology that is increasing from temperate to warmer regions. However, greenhouse protects crops in a bad weather condition, but high temperature and humidity in the tropics have a converse effect on a production of crops. Therefore, in these regions, it is necessary to reduce the temperature inside the greenhouse. Since the design of the cooling system is highly dependent on environmental conditions, it is difficult to develop an appropriate system that provides local climate conditions for product growth. Therefore, in this research, the performance of fan-pad cooling system was studied in different climatic conditions. For this purpose, the greenhouse environment was first modeled using TRNSYS software. After verifying the model with experimental results, the system's ability to cool the greenhouse and system performance was evaluated relative to the parameters of air velocity, temperature and humidity ratio. The results showed that in ambient conditions with dry bubble temperature and humidity ratio less than 40˚C and 0.015 kg/kg, direct evaporative cooling system (fan-pad) at an air velocity of 1.25 m/s was a suitable method for cooling the greenhouse and provides suitable conditions for product growth. Also, the results showed that in the case of moisture content greater than 0.015 kg/kg, the evaporative cooling system alone could not cool the greenhouse.

Language:
Persian
Published:
Journal of Researches in Mechanics of Agricultural Machinery, Volume:8 Issue: 1, 2019
Pages:
107 to 116
magiran.com/p2035139  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!