Evaluation of cumulative kidney activity in pediatric nuclear scan of the bladder using conjugate view method and four different techniques for correcting background radiations

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background

At present, in nuclear medicine to calculate the cumulative activity of various organs, different techniques are being used to correct the background radiations in the conjugate view method. Each of these techniques considers the effect and weight of background radiations to a different extent. These background radiations can cause errors in cumulative activity calculations. The purpose of this study was to evaluate and compare different techniques of correcting background radiations to each other in calculating kidney cumulative activity during the nuclear scan of the bladder in children.

Methods

This study was Cross-sectional and performed for patients who were referred to Isfahan Shahid Chamran Hospital between December 2019 and June 2020. In this study using Foley, 1 mCi of TC-DTPA radio-pharmaceutical that was diluted with normal saline was injected into the patientchr('39')s bladder, then images recorded by gamma cameras were extracted at 2, 5, 10, and 20 minutes, Finally with ROI drawing around kidney with having vesicoureteral reflux, Cumulative renal activity was calculated with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method Eventually, the data was Eventually, the data was compared to each other to determine how much weight each of these techniques consider for background radiations.

Results

Cumulative kidney activity after calculation with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method were 14.970±4.776, 13.544±4.357, 13.885±4.451, 13.879±4.449 mCi.min. respectively After comparing the calculated cumulative activity without correcting the background radiations with the cumulative activity calculated by the three techniques of correcting the background radiations such as the conventional method, Buijs method, and Kojima method, the value (P<0.05) was obtained in all cases, which shows that elimination of background radiations is significantly meaningful in the calculations of cumulative activity in the conjugate method for nuclear exams

Conclusion

after comparing correcting background radiations techniques to each other, it was determined that the conventional method technique considers the effect and weight of background radiations more than the two other techniques such as the Buijs method and Kojima method in cumulative activity calculations.

Language:
Persian
Published:
Tehran University Medical Journal, Volume:79 Issue: 7, 2021
Pages:
499 to 506
magiran.com/p2331650  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!