Accuracy and Precision of Tympanic Temperature in the Reflection of Core Temperature

Abstract:
Background and Aim
Monitoring of patient's temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has been questioned. The aims of this study were (a) to determine accuracy and comparing tympanic temperature with rectal temperature as a gold standard and (b) to determire Precision (Repeatability) of tympanic temperature with single measurement.
Material and Method
This was a descriptive-comparative study with the sample size of 336 subjects, executively selected from the patients who admitted to Rasool Akram Hospital in Tehran. The patients were 16-85 years old. The tympanic temperatures were measured using the Braun ThermoScan type 6020 and the rectal temperatures were measured using the type M9380226 that both thermometers had 0.1 ºC internal error. The tympanic temperatures were measured twice per side with 1 minute of cooling off in each subject.
Result
Paired t-test showed that there was statistical difference between right and left tympanic temperature with rectal temperature (P<0.0001), however, no differences between the second measurement of right tympanic temperature (P=0.172), twine measurements of left tympanic temperature (P=0.100) and also between right and left tympanic temperatures (P=0.500) were found. The Bland-Altman analysis showed that the mean rectal temperatures were 0.23ºC more than the mean of tympanic temperatures, with ranges of agreement between 0.98ºC to 0.51ºC for right tympanic temperatures and the limits of agreement between -0.88ºC to 0.41ºC for left tympanic temperatures. Rectal temperatures showed that there was good correlation between right and left tympanic temperatures (r=0.78, P<0.0001 and r= 0.84, P<0.0001) respectively.
Conclusion
Despite high correlation between the variables (rectal and tympanic temperature), there were clinically and statstically significant differences between them. Also the sensitivity of tympanic temperature was unacceptably low with the number of patients with fever. Therefore, it is concluded that tympanic temperature can’t exactly reflect rectal temperature. Due to acceptable precision and ignorable bias, the tympanic method for temperature measurement can be used, though it is not perfect alternative for rectal route.
Language:
Persian
Published:
Iran Journal of Nursing, Volume:19 Issue: 47, 2006
Page:
57
magiran.com/p435902  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!