Evaluation of the Diagnostic Value of Abdominal Sonographic Measurement of Lower Uterine Segment Thickness in Uterine Rupture during Caesarean Section and Determine its Associated Factors

Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Introduction
The measurement of the lower uterine segment (LUS) thickness before labor predicts hazardous complications of vaginal birth after cesarean section (VBAC). Vaginal birth after cesarean is one of the most effective methods used to reduce the incidence of cesarean section. Therefore, this study was carried out to evaluate the diagnostic value of sonographic measurement of lower uterine segment (LUS) thickness in uterine rupture during cesarean section and its associated factors in women with and without previous cesarean section.
Methods
This prospective cohort study was conducted among 168 pregnant women in two groups of with and without the history of cesarean section (84 individuals per group) referred to Ardabil Alavi Hospital, Ardabil, Iran, in 2016. The thickness of the LUS was determined through transabdominal ultrasonography between the gestational ages of 36 to 40 weeks. At the time of cesarean section, the thickness of the women’s LUS and newborns’ weight and Apgar score were measured and recorded. Additionally, uterine rupture was recorded in patients with the past history of cesarean section. Moreover, the relationship between the LUS thickness and maternal age, gestational age, the indication for previous cesarean section, interdelivery interval, embryo weight, and abnormalities of erythrocyte were determined. Data analysis was performed using descriptive statistics and t-test in SPSS software, version 16.
Results
According to the pre-operative assessments, the LUS thickness in the women with and without the history of cesarean section were 4.26±1.99 mm and 6.11±1.6 mm, respectively (P˂0.001). According to the findings obtained from sonography before and during the operation, there was a significant difference between the groups in terms of LUS thickness (P0.05). Based on the results, the LUS thickness of 1.8 mm was considered as the critical cutoff value for predicting uterine rupture.
Conclusion
The measurement ofLUS thickness is a non-invasive technique to predict the uterine rupture, which leads to increased rate of VBAC.
Language:
Persian
Published:
Iranina Journal of Obstetrics Gynecology and Infertility, Volume:21 Issue: 1, 2018
Pages:
22 to 31
magiran.com/p1811276  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!