Introduction of low to high frequencies bispectrum rate feature for deep sleep detection from awakening by electroencephalogram

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background
Accurate detection of deep sleep (Due to the low frequency of the brain signal in this part of sleep, it is also called slow-wave sleep) from awakening increases the sleep staging accuracy as an important factor in medicine. Depending on the time and cost of manually determining the depth of sleep, we can automatically determine the depth of sleep by electroencephalogram (EEG) signal processing. In this paper a new EEG bispectrum based feature is introduced for deep sleep discrimination.
Methods
This cross-sectional study was conducted at Isfahan University of Medical Sciences, Faculty of Advanced Technologies in Medicine, from February to October 2017. In this study a gray scale image was made of electroencephalogram bispectrum amounts and converted to binary image with Otsu’s Thresholding. Then the ratio of white bits in the above of the secondary diagonal to white bits in the down of secondary diagonal (low to high frequencies bispectrum rate) is extracted as a new feature. This feature is an effective method for detecting deep sleep from awakening.
Results
One of the important methods in biomedical signal processing is the use of the power spectrum or signal energy. In sleep studies, energy-related features have also been used to determine the depth of sleep. Low to high frequencies bispectrum rate is able to separate deep sleep from awakening by accuracy of 99.50 percent, while energy-based features as one of the most important approaches to sleep classification do not have this ability.
Conclusion
In this study we show that “Low to high frequencies bispectrum rate" feature has this capability to use in sleep staging. It is not used in previous works. The accuracy obtained in deep sleep separation from the awakening with the introduced feature (99.50 percent) is greater than the accuracy obtained by all the energy-based features (The simultaneous use of the 6 bands energy leads to 99.42 percent accuracy). This feature indicates the ratio of the phase coupling at low frequencies to high frequencies and can be used in all cases where the bispectrum is used (such as determining the depth of anesthesia).
Language:
Persian
Published:
Tehran University Medical Journal, Volume:76 Issue: 5, 2018
Pages:
326 to 330
magiran.com/p1865065  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!