Survey of indicator toxicity of Isfahan south of wastewater treatment plant by using of daphnia magna

Abstract:
Introduction
Bioassay is necessary for assessment of pollution. Because physical and chemical taste are not enough for assessment of potential effects on water ecosystem. Bioassay tests have alot of scientific value inanition doing of them is easy and need less time, also need less space, laboratory equipment’s and expenditure. Therefor such tests have found special attention in water pollution control measure. So whit determine of effluent toxicity and survey of its effects on water ecosystem by bioassay method, can determine the degree and the kind of treatment that are necessary to having optimum condition for water ecosystem. In this research survey of indicator toxicity of Isfahan south wastewater treatment by daphnia magna has been studied.
Materials And Methods
In this study experiments were done on samples of wastewater that has been taken from Isfahans south wastewater treatment (samples has been taken from four place, influent raw wastewater, before and after primary settling tank and after secondary settling tank). Primary daphnia were couch from there living sites, then one of them were cultured alone, after infants of primary daphnia were used for culture in large amount. After prepering necessary dilution of wastewater samples by doing necessary experiments LC50-48-h toxic unit, efficiency of different units and total of wastewater treatment plant were determined.
Findings
Results reveal that LC50-48-h of influent wastewater is 30%(v/v) and toxic unit is 3.33 and LC50-48-h of wastewater before primary (after preliminary treatment) settling tank, after primary settling tank and after secondary settling tank was determined 32%, 85% and 32% (v/v) respectively, that was on the basis acute toxic unit (ATU) 3.125, 1.92, and 1.76 respectively, efficiency of preliminary treatment in reducing toxicity were determined 6% and efficiency of primary treatment secondary treatment and whole of treatment plant in reducing toxicity were determined 38.4%, 8% and 50% respectively.
Conclusion
Data of this research show that bioassay are necessary for assessment of wastewater and control of water pollution. So bioassay can be used as a suitable method for assessment of effect and efficiency of different treatment units and control of toxicity as base information for monitoring of effluent and due to increasingly developing of wastewater treatment systems in Iran, that is necessary appropriate strategy be under taken to monitoring the effluent. The result of this research and same research can be useful.
Language:
Persian
Published:
Page:
57
magiran.com/p206638  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!