Investigation of Microbial Contamination in Surfaces and Waterlines of Dental Units in Terms of Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, and Coliforms

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background and aim

Water supply systems and various parts of dentistry unit have the ability to aggregate biofilms and thus the transmission of dangerous diseases to staff and patients. The aim of this study was to determine the bacterial contamination of surfaces and water lines of dental units of health center (Qods 2) in Divandareh city.

Material and methods

This cross-sectional descriptive study was conducted on dental units of the health center (Qods 2) in Divandareh city in 2019. 125 samples were collected from different parts of the units including unit lamp handle, lamp ON/OFF power button, open/close bolt of unit water, setting switch button (before and after disinfecting), and the inlet and outlet water of units. The samples were tested for Staphylococcus aureus, Pseudomonas aeruginosa, Coliforms and Escherichia coli.

Results

The results of this study showed that all samples collected from the studied parts of the units including unit lamp handle, lamp ON/OFF power button, open/close bolt of unit water, and setting switch button were positive as presence of Staphylococcus aureus, Pseudomonas aeruginosa, and coliforms before and after disinfection. Also, the unit lamp handle and setting switch button were positive as Escherichia coli. The inlet and outlet water were also positive for all the studied bacteria. The number of Staphylococcus aureus bacteria in the handle of the unit lamp before disinfection (210±80.5 CFU/ml) and in the ON/OFF button of the lamp after disinfection (300±82.6 CFU/ml) were higher than the permissible amount (200 CFU/ml). Also, the number of Pseudomonas aeruginosa bacteria detected in setting switch button, before disinfection, was higher (200±75.2) than the allowable value.

Conclusion

According to the obtained results, the contamination level of water and surface of the studied dental units was high. Also, identifying of the considerable number of bacteria at the different surfaces of the units, indicating the improper use of the disinfectants and the possibility of biofilms presence in the unit waterlines.

Language:
Persian
Published:
Journal of Environmental Health Engineering, Volume:8 Issue: 2, 2021
Pages:
69 to 79
magiran.com/p2272196  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!