Comparative study of pain and mucosal injury in tracheal suctioning with foley and nelaton catheters in patients admitted to the intensive care unit

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Introduction

One of the important nursing interventions in intensive care unit is tracheal suctioning to drain airway secretions. Although this procedure is necessary and useful for managing patients' airways, it is sometimes painful and causes mucosal injury, so it is necessary to try to find tools or methods with the least injury. The purpose of this study was to determin and compare pain and mucosal injury in tracheal suctioning with foley and nelaton catheters in patients admitted to the intensive care unit of selected hospitals affiliated with Alborz University of medical sciences in 2022. 

Methods

The current study was a two-group experimental study, and its statistical population was all patients hospitalized in the intensive care unit of Alborz Karaj Hospital in the first half of 2022. Based on the inclusion criteria, 60 patients were selected through the available sampling method and randomly assigned to two groups: suction with Foley catheters and suction with Nelaton catheters. Patients were suctioned for three days or 12 times as needed and were compared in terms of pain intensity and the amount of mucosal damage caused by suction. In order to collect data, the demographic information form of the patients, Behavioral Pain Scale (BPS) and the observational checklist of mucosal injury were used to evaluate the mucosal damage. The data were analyzed with SPSS21 statistical software and using Independent t-tests, Fisher's exact and chi-square tests. 

Results

There was no statistically significant difference between the two groups in terms of demographic variables. Before suctioning, there was no statistically significant difference between the pain intensity of the two groups of patients at any of the 12 times (P>0.05). But after suction, this difference in the first (P=0.005), second (P=0.003), third (P=0.011), fifth (P=0.017), sixth (P = 0.016), the seventh (P = 0.006), the eighth (P = 0.003), the ninth (P = 0.017) and the tenth (P = 0.017) were significant and suction with Foley catheter compared to Nelaton catheter had less pain (P<0.05). In the case of mucosal injury, there was a significant difference between the two groups at the ninth (P=0.029), tenth (P=0.047) and twelfth (P=0.020) times, and the number of people who suffered after suction There were mucosal damage in the Foley catheter suction group compared to the Nelaton suction group.

Conclusion

Since the use of Foley catheters for suctioning the tracheal tube of patients hospitalized in the intensive care unit causes less pain and mucous membrane than the Nelaton catheters, it is suggested that an arrangement be made to use this method for suctioning the tracheal tube. Patients should be given more attention..

Language:
Persian
Published:
Iranian Journal of Rehabilitation Research in Nursing, Volume:9 Issue: 3, 2023
Pages:
33 to 46
magiran.com/p2600672  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!