Designing and Assessing the Validity and Reliability of the Bayley-III Test Examiner Clinical Performance Scale

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Objective 

In recent years, the infant development and assessment programs have received attention by the health system of Iran. In this regard, the training of examiners for performing the Bayley tests has become one of the needs of the health system. This study aims to design and evaluate the validity and reliability of the Bayley-III examiner clinical performance scale.

Materials & Methods 

this study, participants were Bayley-III test examiners from medical universities in Iran, who were selected using a purposive sampling method. First, in focused group discussion sessions with 10 Bayley-III test experts, the items of instrument were formulated. Then, to evaluate the face validity, the questionnaire was sent to a panel of expert consisting of 8 Bayley-III experts and examiners and they were asked to rate the items from 1 to 5 in terms of importance. The items with an impact score of less than 1.5 were deleted, and other items were revised, if needed. To evaluate content validity, the questionnaire was sent to 10 Bayley-III test experts, and then the content validity ratio (CVR) and content validity index (CVI) were measured. The items with CVR <0.6 and CVI <0.7 were deleted. The reliability of the instrument was assessed by calculating the inter-rater reliability, test re-test reliability, and internal consistency. Quantitative data analysis was done in SPSS software, version 22.

Results 

The instrument with 66 items, including 32 items for the cognitive domain, 22 items for the language domain (13 for receptive and 9 for expressive components), 12 items for the motor domain (9 for fine and 3 for gross motor skills), and 14 items for the general section, was assessed in stability and reliability. The intraclass correlation coefficient (ICC) for the test re-test reliability was obtained 0.83 for the specific section and 0.86 for the general section. The ICC for the inter-rater reliability was 0.80 (95% CI: 58-82). The highest correlation value was related to the cognitive scale (0.88), and the lowest value was for the gross motor skill subscale (0.76). The kappa coefficient for the inter-rater reliability of the general section was above 0.7. The kappa coefficient for the specific section ranged from 1 to 0.35. The Cronbach’s α for the internal consistency of the general section was 0.76. 

Conclusion 

The designed questionnaire is a valid and reliable tool to evaluate the clinical performance of Bayley-III test examiners in Iran.

Language:
Persian
Published:
Archives of Rehabilitation, Volume:24 Issue: 4, 2024
Pages:
566 to 585
magiran.com/p2694750  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!