The sensitivity, specificity, and accuracy of Creatinine test and human chorionic gonadotropin (HCG) test of cervical mucus discharge to diagnose preterm premature rupture of membranes (PPROM)

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Introduction

Premature Rupture of Membranes (PROM) is one of the common problems of midwifery, which its early diagnosis is essential in the process of treatment and prevention of pregnancy adverse outcomes. Therefore, this study was performed with aim to evaluate the diagnostic accuracy of Creatinine and human chorionic Gonadotropin (HCG) test of cervical mucusdischarge to diagnose PROM in pregnant women.

Methods

This prospective study was conducted in 2017-2018 on 150 pregnant women with gestational age of 24 to 37 weeks and suspected to PROM. The subjects were divided into two groups of Rupture Membranes (Pooling and Fern test both of them were positive) and control group (Pooling and Fern test both of them were negative and AFI was normal). Creatinine was measured with Automated Analyzer method (Prestige device) and βHCG with Chemi-luminescence Signal Band method (Abbott device). Cut-off point and diagnostic accuracy were measured for two tests by rock curve. P-value<0.05 was considered statistically significant.

Results

The highest sensitivity and specificity for creatinine in the diagnosis of PPROM was obtained at cut-off point 0.135 and for βHCG at cut-off point 26.78, with sensitivity of 91.7% and specificity 56.1%, and positive predictive value of 39.75% and negative predictive value of 95.52% and overall accuracy was 64.66% and the agreement rate was 0.33 (P <0.001). For βHCG, the sensitivity 58.3% and specificity 63.2%, and positive predictive value 33.33%, and negative predictive value of 82.75% and overall accuracy was 62% and the agreement rate was 0.171 (P=0.023).

Conclusion

The sensitivity and diagnostic power of Creatinine in preterm women was higher than βHCG. Reasonable price, simplicity, and safety are the advantages of both methods. The diagnostic accuracy obtained in this study was low, but due to the limited studies in preterm patients, the clinical use of these markers cannot be recommended or rejected; therefore, more studies are suggested.

Language:
Persian
Published:
Iranina Journal of Obstetrics Gynecology and Infertility, Volume:24 Issue: 5, 2021
Pages:
31 to 39
magiran.com/p2320417  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!