EDTA dentin conditioning and Micro-shear bond strength using SE and SEM

Message:
Abstract:
Background And Aim
The main objective of using adhesive material is the improvement of restorative materials bonding to dentin surface in clean environment. The aim of this study was to investigate the effect of EDTA on bond strength of composite resin to dentin surface when used at different times and concentrations prior to application of adhesive systems by employing Scanning Electronic Microscope (SEM).
Materials And Method
A total of 100 dentin samples were prepared from 50 human premolars. These samples were divided into two groups according to bonding type (Clearfil SE Bond =group I, Futurbond NR=group II) and each one was classified 5 subgroups according to time and concentration of EDTA as follows: 1 – Control. 2- EDTA 15%, 30 seconds. 3 – EDTA 15%, 60 seconds. 4 – EDTA 24%, 30 seconds. 5 – EDTA 24%, 60 seconds. These samples were conditioned and composite cylinders were adhered to them. After 500 cycles of thermocycling, the testing for micro-shear bond strength was conducted on these samples. Another 10 samples were demineralized for 30 seconds with 6NHCL and deproteinized with 2.5% Naocl for 10 minutes, air dried with desiccators and viewed under SEM. Data were analyzed using one-way as well as three-way ANOVA and Tukey tests.
Results
The mean Micro-shear bond strength in group I (Clearfil SE bond) were: 31.88 (± 13) for subgroup 1, 28.4 (± 13) in subgroup 2, 29.8 (± 9) in subgroup 3, 29.2 (± 11) in subgroup 4, and 32.7 (± 12) in subgroup 5. The mean Micro-shear bond strength in group 2 (Futurbond NR): were: 22.6 (± 10) for subgroup 1, 28.5 (± 9) in subgroup 2, 27.3 (± 10) subgroup 3, 32.4 (± 15) in subgroup 4, and 31.1 (± 14) in subgroup 5. There were no significant differences between the samples conditioned and the ones not conditioned with EDTA, time and the concentration of EDTA applied and also the two bonding types.
Conclusions
EDTA conditioning prior to use of the two bonding agents under investigation in this study did not improve the bonding strength of the self etch systems, neither did the time and the concentration of EDTA applied.
Language:
Persian
Published:
Journal of Islamic Dental Association of IRAN, Volume:21 Issue: 2, 2009
Page:
105
magiran.com/p656168  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!