Evaluation of class V composite restorations microleakage in premolars with/without electric current while applying variant dentin bondings

Message:
Abstract:
Background And Aims
The ability of composite restorations to prevent microleakage needs desirable bonding material for proper sealing. The purpose of this study was to evaluate class V composite restorations microleakage in premolars with/without electric current while applying variant dentin bonding in vitro.
Materials And Methods
120 non-carious human premolars were used for this study and standardized class v cavities were prepared. The tooth roots were cut by discs at a distance of 5 mm from CEJ and pulp tissue was removed. The teeth were divided into six groups of 20. In the first group, electric current was applied, Single bond (3M ESPE, St Paul, MN, USA) with a broom motion attached to the cathode and a sponge containing bonding was used as anode. The used current was 15µA and the Single bond in the second group was used without electricity. Then two bondings PQ1 (Ultradent, Germany) and Optibond solo plus (Kerr, USA) were used with and without electricity. After adhesive application and curing the bonding agents, cavities were restored by a composite (Valux Plus). The root ends were sealed by wax and all teeth surfaces, except 1 mm around the restorations were covered with a nail varnish. The specimens were thermocycled for 1000 cycles and placed in fushin for 24 hours and were then sectioned vertically and examined under a stereomicroscope. Data were scored on a 0-4 scale based on microleakage at the gingival margins and analyzed using Kruskal-Wallis and Mann-whitney test.
Results
Based on the results, the extent of microleakage in the groups of electric current was significantly less than the groups without using the electric current (P=0.05). The lowest degree of microleakage was found in PQ1 group, and the greatest difference between the groups with and without electricity was also found in PQ1 group. Single bond and Optibond Solo Plus with electric current showed a lower degree of microleakge.
Conclusion
The result showed that use of electric current during the application of dental adhesives could reduce the extent of microleakage.
Language:
Persian
Published:
Journal of Dental Medicine, Volume:27 Issue: 2, 2014
Pages:
99 to 107
magiran.com/p1295010  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!